A chemically modified electrode is constructed based on multi-walled carbon nanotube modified glassy carbon electrode (MWCNTs/GCE). It is demonstrated that this sensor could be used for determination of pharmaceutically important compound mefenamic acid (MEF). Differential pulse voltammetry (DPV) experiments of various concentration of MEF showed two linear dynamic ranges. The first linear dynamic range was from 2 μM to 40 μM, and the second linear dynamic range was between 50 μM to 360 μM. A detection limit of 0.21 µM (S/N = 3) was obtained. Under optimal conditions the modified electrode exhibited high sensitivity and stability for determination of MEF, making it a suitable sensor for the submicromolar detection of MEF in solutions. The analytical performance of this sensor has been evaluated for the detection of MEF in human serum, human urine and a pharmaceutical preparation with satisfactory results


MOHAMMAD AFRASIABI, SHOKAT KIANIPOUR , ZEINAB REZAYATI ZAD, ALI BABAEI